CARRINHO (0 ITENS)

Seu carrinho está vazio.

Ir para a loja

Information

Technical Specifications

  • Voltage: 105~305V;
  • Operating frequency: 50/60Hz;
  • Power consumption: <1W or 10VA capacitive;
  • Brightness required to switch on: between 5 and 15 Lux;
  • Brightness at shut-off: up to 30 Lux;
  • Initial state of the contacts: Normally open (NO);
  • Failure mode: Fail-off (FD);
  • Operating mode: activates the load at night and deactivates it during the day (Night On);
  • Delay classification: AR (fast actuation);
  • Technology: microcontroller-based;
  • Surge protection: @1.2×50µs: 10kV;
  • Dielectric strength: ≥ 2500V @ 1 minute;
  • Operating temperature: -5°C to 50°C;
  • Delay, tr = response time (s): (fast 0.5 < tr < 5);
  • Time filter: double delay that prevents unintended activations due to sudden changes in brightness such as lightning, lasers, clouds, etc. Between 2 and 5 seconds to turn on or off;
  • Material: Cup made of polycarbonate (PC) resin with anti-UV protection, base made of polypropylene (PP) copolymer resin, PVC gasket and tin-plated brass pins/terminals;
  • Protection rating: IP67;
  • Warranty: 5 years;
  • Dimensions: ⌀76×43.5×54.8mm;
  • NBR5123 standard;
  • Operation code: T2LDFDRNAR;
  • Inrush Control Technology: exclusive near-zero switching system for the sine wave network, increasing the lifespan of the load and the relay;
  • Indelible marking map of the time of removal and placement in the field;
  • To control loads exceeding the specified capacity, use the Electronic Photocontrol Relay in conjunction with an Exatron Group Control Switch (30, 50 or 60 amperes) available in the under/over voltage control version;
  • Silicon photocell sensor: phototransistor;
  • For this product to function correctly, the minimum required power is 1W;
  • Control power:
Capacity

load (lamps)

VoltageResistiveInductiveCorrected
220V1000W1800VA500VA PF≥0.92
127V1000W1200VA500VA PF≥0.92

Installation

Fit the relay into the NEMA – NBR5123 standard socket in the corresponding positions;

Turn the relay clockwise to lock it.

Night Switch Photocontrol Relay – IP67 Protection

available

Code: LUXON FD67

Description

The Exatron Electronic Photocontroller Relay is a microcontroller-based photoelectric relay ideal for controlling lighting points and other loads. With a high degree of IP67 protection, the LUXON FD67 offers complete protection against dust and protection against temporary immersion in water.

This device keeps lights illuminated in the absence of natural light and is insensitive to sudden changes in brightness, lightning, and headlights. It can be installed with any type of light bulb.

The LUXON FD67 product is a multi-voltage model, operating on night (LN), fault-free (FD), normally open (NA), and with quick activation (AR). It has an IP67 protection rating and a polycarbonate (PC) cover with UV protection.

Download

R$ 42,49

Shipped within 7 business days.
Price* for end consumer

Information

Technical Specifications

  • Voltage: 105~305V;
  • Operating frequency: 50/60Hz;
  • Power consumption: <1W or 10VA capacitive;
  • Brightness required to switch on: between 5 and 15 Lux;
  • Brightness at shut-off: up to 30 Lux;
  • Initial state of the contacts: Normally open (NO);
  • Failure mode: Fail-off (FD);
  • Operating mode: activates the load at night and deactivates it during the day (Night On);
  • Delay classification: AR (fast actuation);
  • Technology: microcontroller-based;
  • Surge protection: @1.2×50µs: 10kV;
  • Dielectric strength: ≥ 2500V @ 1 minute;
  • Operating temperature: -5°C to 50°C;
  • Delay, tr = response time (s): (fast 0.5 < tr < 5);
  • Time filter: double delay that prevents unintended activations due to sudden changes in brightness such as lightning, lasers, clouds, etc. Between 2 and 5 seconds to turn on or off;
  • Material: Cup made of polycarbonate (PC) resin with anti-UV protection, base made of polypropylene (PP) copolymer resin, PVC gasket and tin-plated brass pins/terminals;
  • Protection rating: IP67;
  • Warranty: 5 years;
  • Dimensions: ⌀76×43.5×54.8mm;
  • NBR5123 standard;
  • Operation code: T2LDFDRNAR;
  • Inrush Control Technology: exclusive near-zero switching system for the sine wave network, increasing the lifespan of the load and the relay;
  • Indelible marking map of the time of removal and placement in the field;
  • To control loads exceeding the specified capacity, use the Electronic Photocontrol Relay in conjunction with an Exatron Group Control Switch (30, 50 or 60 amperes) available in the under/over voltage control version;
  • Silicon photocell sensor: phototransistor;
  • For this product to function correctly, the minimum required power is 1W;
  • Control power:
Capacity

load (lamps)

VoltageResistiveInductiveCorrected
220V1000W1800VA500VA PF≥0.92
127V1000W1200VA500VA PF≥0.92

Installation

Fit the relay into the NEMA – NBR5123 standard socket in the corresponding positions;

Turn the relay clockwise to lock it.