Information

Technical Specifications

  • Voltage: 127V~ 60Hz
  • Digital technology.
  • Contact type when de-energized: normally open (NO) – fail-off.
  • Time filter: prevents unintended activations due to sudden changes in light such as lightning, lasers, clouds, etc. Turns on or off in less than 4 seconds (instant type).
  • Lux for turning on: between 3 and 20 Lux.
  • Lux to turn off: less than 80 Lux respecting the hysteresis ratio between on and off (hysteresis): 1.2 to 4 times.
  • Dielectric strength: ≥ 2500V @ 1 minute.
  • Silicon photocell sensor: phototransistor
  • Surge voltage: up to 4000V / 2000A.
  • Power consumption: less than 0.7W;
  • Indelible marking map of the moment of removal and placement in the field.
  • Protection rating: IP 65.
  • Operation code: T2LNFDRNAR
  • Warranty: 1 year.
  • For this product to function correctly, the minimum required power is 1W.
  • Control power:
ResistiveInductiveCorrected
1000 W1200 VA500 VA

 

Installation

Plug the Luxon 1FD relay into the standard NBR5123 socket.

Instantaneous Photoelectric Relay 127 V – FD (Fault Off)

available

Code: LUXEN 1FD

Description

The Exatron instantaneous photoelectric relay (LUXEN 1FD) is ideal for switching lighting points and other loads, keeping lights on in the absence of natural light and is insensitive to sudden changes in brightness, lightning and headlights; it can be installed with any type of lamp.
This product has a normally open (NO) contact, keeping the lights off during the day and night in case the relay becomes inoperative.

ATTENTION: For safe installation of photoelectric relays, the use of a relay socket is recommended.

Download

Information

Technical Specifications

  • Voltage: 127V~ 60Hz
  • Digital technology.
  • Contact type when de-energized: normally open (NO) – fail-off.
  • Time filter: prevents unintended activations due to sudden changes in light such as lightning, lasers, clouds, etc. Turns on or off in less than 4 seconds (instant type).
  • Lux for turning on: between 3 and 20 Lux.
  • Lux to turn off: less than 80 Lux respecting the hysteresis ratio between on and off (hysteresis): 1.2 to 4 times.
  • Dielectric strength: ≥ 2500V @ 1 minute.
  • Silicon photocell sensor: phototransistor
  • Surge voltage: up to 4000V / 2000A.
  • Power consumption: less than 0.7W;
  • Indelible marking map of the moment of removal and placement in the field.
  • Protection rating: IP 65.
  • Operation code: T2LNFDRNAR
  • Warranty: 1 year.
  • For this product to function correctly, the minimum required power is 1W.
  • Control power:
ResistiveInductiveCorrected
1000 W1200 VA500 VA

 

Installation

Plug the Luxon 1FD relay into the standard NBR5123 socket.